UC100 -Universal Controller

Applications

  • Cumulative Online Batch Weigher
  • Bagging System 
  • Online Check Weigher
  • Jumbo Bagging

Suitable Applications

Models And Specification
Indicator
Power
Power SupplyVoltage 90V to 245V AC,
max 30W
ControllerRTC Built,
32-bit high speed ARM7
A/D Converter
Type24-bit Delta Sigma
Analogue Input Range0 mV to 25 mV
Linearity<0.03% FS
Gain Drifting2PPM/◦C
Conversion Rate600 Samples/Sec
Internal Resolution1 in 30,000
Display &
Keypads
LCD Display4 lines 20 character
LED Display6 digits 7 Segment LED Display (size : 0.56″)
KeypadsCapacitive Sense 17 alphanumeric keys
Calibration & Weighing
CalibrationDigital calibration by using standard weights
Weighing FunctionsAuto Zero, Power On Tare
Inputs& Outputs
Input Load cell
Serial Ports Single RS485 Half Duplex Port and Two RS232 ports.
Connectors R/A pluggable terminal connectors
Collector
output
8 isolated open collector outputs for 500mA load current max
Isolated Inputs 8 isolated inputs for 24 VDC max
Load cells
Excitaton5 VDC
Load cellsDrives 4 Load cells of 350 Ω
Mech
dimensions
Cabinet Size200mm (L)*125mm (H)*207mm (W)
Cutout Details122mm (H)*206mm (W) with mounting hole 240mm (L) *60mm (H) at 4 holes 5mm diameter
Gross Weight3.10 Kg
Environmental
Operating Temperature -10◦C to 40◦C
Storage Temperature -25◦C to 70◦C
Relative Humidity 90% R.H without dew
IP Level Front panel IP 55


SMART-UC100

Application.

  • Cumulative Online Batch Weigher
  • Bagging System 
  • Online Check Weigher
  • Jumbo Bagging
  • Smart BMI
  • Smart Counting System
Cumulative Online Batch Weigher I / O Details
S. No.Input parameterDescriptionOutput parameterDescription 
1STARTTo start the batch cycleCOARSEFeed hopper Operation 
2STOPTo STOP the batch cycle FINEFine Gate operation 
3AUTO/MANUALAuto manual I/PERRORSystem Error
4GATE CLOSEWeigh  Hopper Gate close signal DISCHARGEWeigh hopper Operation 
5LEVELMaterial Level SignalBATCH ENDBatch Completion O/P
6TAREEmpty Hopper TARE FunctionBATCH STATUSSystem ON status O/P 
7LOW PRESSUREAir pressure signal 
Bagging System  I / O Details
S. No.Input parameterDescriptionOutput parameterDescription
1STARTTo start the batch cycleCOARSEFeed hopper Operation 
2STOPTo STOP the batch cycle MEDIUMMedium Gate operation
3KEYLOCKTo lock the keypadFINEFine Gate operation 
4GATE CLOSEWeigh  Hopper Gate close signal ERRORSystem Error
5LEVELMaterial Level SignalHAMMERINGHammering Function for material settlement 
6BAG CLAMPTo clamp the BagBAG CLAMPBag Clamp and Declamp function 
7TAREEmpty Hopper TARE Function BATCH ENDBatch Completion O/P
8DISCHARGEMaterial Discharge from Weigh hopperPROCESSSystem ON status O/P
9SLIDE GATESlide gate function 
Online Check Weigher  I / O Details
S. No.Input parameterDescriptionOutput parameterDescription 
1SENSORProduct Detection SensorACCEPTAccept Product O/P
2LOW PRESSURELow Air pressure signal LOW REJECTProduct Low reject O/P
3TARETARE Function HIGH REJECTProduct HIGH  reject O/P
4KEY LOCKTo lock the keypadREJECTReject for Buzzer 
5STARTTo START the ConveyerERRORSystem Error 
6STOPTo STOP the ConveyerAVERAGE ERRORCumulative product Average
7RUNRun the conveyer 
Jumbo Bagging  I / O Details
S. No.Input parameterDescriptionOutput parameterDescription
1STARTTo start the batch cycleCOARSEFeed hopper Operation 
2STOPTo STOP the batch cycle MEDIUMMedium Gate operation
3PAUSE/CONTINUEBatch PAUSE and Continue FINEFine Gate operation
4COMP SIGNAL HIGHBag Lifting Cylinder HI SignalVIBRATORVibrator O/P during shacking
5COMP SIGNAL LOWBag Lifting Cylinder Low SignalCOMP CYLINDERBag shacking Cylinder O/P
6AIR PRESSURELow Air pressure signalBATCH ENDBatch Completion O/P
7SLIDE GATESlide gate Signal AIR BLOWTo Inflate the bag
8LEVELMaterial Level Signal

UC100 – Universal Controller(LS)

Application.

  • Universal testing machine
  • Box Compression test
  • Compression test
Models And Specification
Indicator
Power
Power Supply1Voltage 90V to 245V AC, max 30W
ControllerRTC Built, 32-bit high speed ARM7
A/D Converter
Type24-bit Delta Sigma
Analogue Input Range0 mV to 25 mV
Linearity<0.03% FS
Gain Drifting2PPM/◦C
Conversion Rate10 SPS or 600 Samples/Sec
Internal Resolution1 in 30,000
Display &
Keypads
LCD Display4 lines 20 character
LED Display6 digits 7 Segment LED Display (size : 0.56″)
KeypadsCapacitive Sense 17 alphanumeric keys
Calibration & Weighing
CalibrationDigital calibration by using standard weights
Weighing FunctionsAuto Zero, Power On Tare
Inputs& Outputs
Input Load cell
Serial Ports Single RS485 Half Duplex Port and Two RS232 ports.
Connectors R/A pluggable terminal connectors
Collector Output 8 isolated open collector outputs for 500mA load current max
Isolated Inputs 8 isolated inputs for 24 VDC max
Load cells
Excitation5 VDC
Load cellsDrives 4 Load cells of 350 Ω
Mech
Dims
Cabinet Size200mm (L)*125mm (H)*207mm (W)
Cutout Details122mm (H)*206mm (W) with mounting hole 240mm (L) *60mm (H) at 4 holes 5mm diameter
Gross Weight3.10 Kg
Environmental
Operating Temperature -10◦C to 40◦C
Storage Temperature -25◦C to 70◦C
Relative Humidity 90% R.H without dew
IP Level Front panel IP 55